Features:Suit for use in DC or pulse electronic circuits in instruments.
Technical data:
Item | Characteristics | |
Temperature range | -40~+85℃ | -25~+85℃ |
Rated voltage range | 25~100V | 160~550V |
Capacitance range | 100~2200μF | 10~100μF |
Capacitance tolerance | -10~+50% ±20% | |
Leakage current | I≤0.03CR UR+20(μA) | |
Load life | 1000 Hours at 85℃ |
Dimensions:
CD12、CD15 mm
D±0.5 | 16 | 19 | 21 | 26 | |
L±2.0 | 35 | 50 | 45 | 50 | 60 |
CD13、CD14 mm
D±0.5 | 21 | 26 | 30 | 34 | 42 | ||
L±3.0 | 45 | 50 | 60 | 60 | 60 | 80 | 80 |
Nominal capacitance、rated voltage and case size table:
25 | 32 | 50 | 63 | 100 | 160 | 300 | 450 | 500 | 550 | |
10 | 19x50 | 19x50 | 19x50 | 26x50 | ||||||
22 | 19x50 | 21x45 | 26x50 | 26x50 | ||||||
33 | 16x35 | 16x35 | 21x45 | 26x50 | 26x60 | 26x60 | ||||
47 | 16x35 | 16x35 | 16x35 | 16x35 | 26x50 | 26x60 | 26x60 | 26x60 | ||
100 | 16x35 | 16x35 | 16x35 | 16x35 | 19x50 | 21x45 | 26x60 | 34x80 | ||
150 | 16x35 | 16x35 | 19x50 | 19x50 | 19x50 | 21x45 | 30x60 | 34x80 | ||
220 | 19x50 | 19x50 | 19x50 | 19x50 | 21x45 | 21x45 | 34x60 | 42x80 | ||
330 | 19x50 | 19x50 | 19x50 | 19x50 | 26x60 | 26x60 | 34x80 | |||
470 | 19x50 | 19x50 | 21x45 | 21x45 | 30x60 | 30x60 | ||||
680 | 21x45 | 26x60 | 26x60 | 26x60 | 34x60 | 34x60 | ||||
1000 | 21x45 | 26x60 | 26x60 | 26x60 | 34x80 | 34x80 | ||||
2200 | 26x60 | 30x60 | 30x60 | 30x60 | 34x80 |